==Phrack Magazine==
|
|
|
|
Volume Seven, Issue Forty-Eight, File 9 of 18
|
|
|
|
---------------------------------------------------------------------------
|
|
Information about Northern Telecom's FMT-150B/C/D
|
|
Written by StaTiC
|
|
(statik@free.org)
|
|
---------------------------------------------------------------------------
|
|
|
|
Ok, I know someone wrote an article in Phrack about the
|
|
FMT-150B/C/D, but I figured I should write some more. I am not going to
|
|
write the same info that FyberLyte wrote, in fact I recommend you go and
|
|
check it out. It is in Phrack #44-13. This is some stuff I obtained,
|
|
that I figured the rest of the world would be interested in.
|
|
|
|
Included info: Connecting a FMT-150 to a Rockwell OS-35
|
|
Connecting Environmental Alarms to the FMT-150
|
|
Procomm Script to Perform Configuration of FMT-150
|
|
FMT-150 Configuration Checklist
|
|
Glossary of Terms
|
|
|
|
|
|
------------------------------------------------------------------------------
|
|
|
|
INSTRUCTIONS FOR X-CONNECTING FMT-150 CUSTOMER OUTPUT TO
|
|
ROCKWELL OS-35 INPUTS
|
|
|
|
A pin block will be provided at the central office location, in the
|
|
bay equipped with FMT-150 equipment. The pin block will provide
|
|
the termination points for the Rockwell OS-35A and the FMT-150
|
|
customer output alarms. Each pin block will be able to support a
|
|
maximum of 16 FMT-150 systems, see pin block diagram.
|
|
|
|
Wiring of the FMT-150 customer outputs points and the OS-35A points
|
|
will be done by the vender on the back of the pin block.
|
|
|
|
Once a FMT-150 system has been certified the certification team
|
|
will be responsible for x-connecting the FMT-150 customer output
|
|
alarm points to the appropriate OS-35A points on the front of the
|
|
pin block. Completion of this x-connecting will allow FMT-150
|
|
system alarms originating either from the CO or the RT to be
|
|
transported via the OS-35A back to the Lightwave and Radio Alarm
|
|
Center.
|
|
|
|
IMPORTANT, MBT CERTIFICATION TEAMS X-CONNECT ONLY THE FMT-150 THAT
|
|
IS BEING PUT INTO SERVICE AND ONLY AFTER THE ELECTRONICS ARE
|
|
CERTIFIED.
|
|
|
|
The FMT-150 16 customer outputs are defined as follows:
|
|
|
|
OUTPUT ALARM OUTPUT ALARM
|
|
------ ----- ------ -----
|
|
1 BAY MAJOR 9 MI3 ALARM #3
|
|
2 BAY MINOR 10 HSA ALARM
|
|
3 OPT A FAIL 11 HSB ALARM
|
|
4 OPT B FAIL 12 DS1 GRP FAIL
|
|
5 STX TX 13 SYSTEM ID CLLI
|
|
6 STS RX 14 COMM. EQUIP. ALARM
|
|
7 M13 ALARM #1 15 NODE #1 CO
|
|
8 M13 ALARM #2 16 NODE #2 REMOTE
|
|
|
|
The Rockwell OS-35A provides a total of 32 separate alarm points.
|
|
The first 16 points with the exception of point 13 have been
|
|
multiplied on the pin block to provide x-connect points for a total
|
|
of 16 FMT-150 systems, see pin block diagram.
|
|
|
|
On the pin block x-connect the designated (1 of 16) FMT-150 system
|
|
customer outputs, pins 1-12 and 14-16 to the appropriate OS-35A
|
|
pins 1-12 and 14-16, see pin block diagram.
|
|
|
|
Pins 17-32 on the pin block going to the OS-35A will be used for
|
|
x-connecting the customer output #13 from each FMT-150 system.
|
|
Customer output #13 provides the system ID for the FMT-150, see pin
|
|
block diagram.
|
|
|
|
X-CONNECT CUSTOMER OUTPUT #13 FROM FMT-150 SYSTEMS IN
|
|
THIS SEQUENCE
|
|
|
|
OS-35A FMT-150 System
|
|
------ --------------
|
|
PIN 17 SYSTEM 1
|
|
PIN 18 SYSTEM 2
|
|
: :
|
|
: :
|
|
PIN 31 SYSTEM 15
|
|
PIN 32 SYSTEM 16
|
|
|
|
AGAIN, WIRE ONLY THE FMT-150 SYSTEM THAT IS BEING PUT INTO SERVICE
|
|
AND ONLY AFTER CERTIFICATION OF ELECTRONICS HAVE BEEN COMPLETED.
|
|
|
|
After x-connects have been completed on FMT-150 system that has
|
|
been certified, contact the Alarm Center at (313) 223-9688 and
|
|
verify that all 16 customer output alarm conditions at both the CO
|
|
and RT can be activated and are reporting via the OS-35A back to
|
|
the alarm center.
|
|
|
|
The Lightwave Alarm Center will monitor the FMT-150 system for a 24
|
|
hour quiet period for alarms. During this 24 hour period if no
|
|
alarms are detected by the Lightwave Alarm Center, the FMT-150 will
|
|
be considered certified for alarming and ready for continual
|
|
monitoring.
|
|
|
|
If during the 24 hour quiet period the alarm center receives alarms
|
|
from the FMT-150 system, it will not be certified for continual
|
|
monitoring and it will be the responsibility of the MBT
|
|
Certification Teams to resolve those alarms.
|
|
|
|
|
|
----------------------------------------------------------------------------
|
|
|
|
INSTRUCTIONS FOR CROSS CONNECTING ENVIRONMENTAL ALARMS TO
|
|
THE FMT-150 INPUTS.
|
|
|
|
Environmental alarms at remote locations may be connected to the
|
|
FMT-150 customer inputs. If more than one system exists, these
|
|
alarms should only be connected to the first. Since many remotes
|
|
will not be equipped with all of these alarms, a checklist has been
|
|
provided on the system acceptance sheets to indicate which have
|
|
been wired. The alarms provided for are Smoke Detector, Sump Pump,
|
|
Open Door, AC Power Fail, HI-LO Temperature, Rectifier Fail, and
|
|
Battery Float. These are wired to pins D8 through E9 on the
|
|
FMT-150 backplane. See Shelf Backplane Detail, attached.
|
|
|
|
All Customer Inputs are software connected to Customer Output #12.
|
|
They will also bring in Bay Minor (Output #1) or Bay Major (Output
|
|
#2) as appropriate. Inputs #1 (Smoke Detector) and #2 (Sump Pump)
|
|
are latching inputs that can only be cleared by accessing the MCU
|
|
with a VT100 terminal. See Section 321-3211-01, DP 3003, page 2.
|
|
|
|
FMT-150 systems using external inputs for environmental alarms and
|
|
which use E2 telemetry rather than the OS-35 MUST be provided with
|
|
type NT7H90XH Maintenance Control Units at both ends.
|
|
|
|
External alarm operation and telemetry if equipped, should be
|
|
verified with the Alarm Center during acceptance.
|
|
|
|
|
|
|
|
|
|
--------------------------------------------------------------------------
|
|
Procomm Script for Accessing FMT-150B/C/D
|
|
|
|
;**********************************************************************
|
|
;* *
|
|
;* FMT150.CMD Version 5.00 Dec 18, 1990 *
|
|
;* Please Destroy all previous versions of this program! *
|
|
;* *
|
|
;* NOTE: Procomm is a product of Datastorm Technologies *
|
|
;**********************************************************************
|
|
;
|
|
; The script FMT150.CMD was written to automatically perform
|
|
; all configuration commands for the Northern Telecom FMT-150
|
|
; fiber optic multiplexer. Specifically, this script will
|
|
; complete over 125 configuration commands (performance
|
|
; threshold, error correction, and alarm outputs) as outlined
|
|
; in Section 4 of the Michigan Bell Certification Procedure for
|
|
; the FMT-150. This program is compatible with all
|
|
; certification requirements for FMT-150 MCU NT7H90XA or MCU
|
|
; NT7H90XE.
|
|
;
|
|
; Requirements:
|
|
; 1) Toshiba T1000 craft terminal or DOS equivalent.
|
|
; 2) Proper serial cables and adapters.
|
|
; 3) Procomm disk with FMT150.CMD file.
|
|
;
|
|
; Procedure for use:
|
|
; 1) Remove disk from drive, then turn on computer. When the DOS
|
|
; prompt appears insert the PROCOMM disk into disk drive.
|
|
; Enter the command "A:" + <ENTER>.
|
|
; 2) Enter the command "FIXPRN" + <ENTER>.
|
|
; 3) Enter the command "PROCOMM" + <ENTER>.
|
|
; 4) While holding the <ALT> key down, press the <D> key,
|
|
; and select FMT-150 from the dialing menu.
|
|
; 5) Gain access to MCU as normal (press the <ENTER> key 3 times).
|
|
; 6) Once logged in, reset the MCU to factory default by
|
|
; entering "M"(aintenance) "R"(eset) "*"(all) + <ENTER>.
|
|
; It will take approximately three minutes to reconfigure.
|
|
; 7) Gain access to MCU again as in steps 3) & 4).
|
|
; 8) Select the script by pressing <ALT><F5> keys simultaneously.
|
|
; 9) When prompted for command file enter "FMT150" + <ENTER>.
|
|
; 10) Answer questions and away you go!
|
|
;
|
|
; HISTORY: Version 4.00 May 15, 1990 by AQW final release version
|
|
; HISTORY: Version 4.10 Aug 08, 1990 by JBH mod to use VPRINT to divert
|
|
; printer into a better bit bucket, and to correct callback #.
|
|
; HISTORY: Version 4.12 Nov 21, 1990 by EEE to use Customer Inputs
|
|
; HISTORY: Version 5.00 Dec 18, 1990 by JBH to update documentation
|
|
;SN051690000
|
|
;REFNO=5.00
|
|
CLEAR
|
|
PAUSE 1
|
|
ALARM 1
|
|
MESSAGE " "
|
|
MESSAGE " *************************************************"
|
|
MESSAGE " * *"
|
|
MESSAGE " * FMT-150 MCU NT7H90XC\CA CONFIGURATION PROGRAM *"
|
|
MESSAGE " * MCU NT7H90XE\EA CONFIGURATION PROGRAM *"
|
|
MESSAGE " * *"
|
|
MESSAGE " * VERSION 5.00 DEC 18, 1990 *"
|
|
MESSAGE " * *"
|
|
MESSAGE " * MICHIGAN BELL TELEPHONE COMPANY *"
|
|
MESSAGE " * A DIVISION OF AMERITECH *"
|
|
MESSAGE " * *"
|
|
MESSAGE " * *"
|
|
MESSAGE " *************************************************"
|
|
MESSAGE " "
|
|
MESSAGE " "
|
|
MESSAGE " ....TO EXIT THIS PROGRAM AT ANY TIME, PRESS <ESC>...."
|
|
PAUSE 3
|
|
ALARM 1
|
|
|
|
;VARIABLE DOCUMENTATION
|
|
;S0=CLLI A USER INPUT
|
|
;S1=CLLI B USER INPUT
|
|
;S2=CLLI LOCAL USER INPUT
|
|
;S3=YEAR 2 DIGIT USER INPUT
|
|
;S4=MONTH 2 DIGIT USER INPUT
|
|
;S5=DAY 2 DIGIT USER INPUT
|
|
;S6=HOUR 2 DIGIT USER INPUT
|
|
;S7=MINUTE 2 DIGIT USER INPUT
|
|
;S8=SYSTEM ID & USER RESPONSE USED TO CONTROL PROGRAM FLOW
|
|
;S9=SYSTEM NUMBER
|
|
|
|
LABEL1:
|
|
|
|
; note the following statement was superseded in version 4.10 by VPRINT
|
|
;DOS "MODE LPT1:=COM2:" ; REQUIRED TO TURN PRINTER ERROR OFF
|
|
; following flushes the "RUB" buffer
|
|
TRANSMIT "^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H^H"
|
|
CLEAR
|
|
LOCATE 10,2
|
|
MESSAGE "Enter CLLI code for LOCATION A (C.O.) using full 8 or 11 characters:"
|
|
LOCATE 12,2
|
|
GET S0 11 ;CLLI A
|
|
MESSAGE " "
|
|
CLEAR
|
|
LOCATE 10,2
|
|
MESSAGE "Enter CLLI code for LOCATION B (REMOTE) using full 8 or 11 characters:"
|
|
LOCATE 12,2
|
|
GET S1 11 ;CLLI B
|
|
MESSAGE " "
|
|
CLEAR
|
|
LOCATE 10,2
|
|
MESSAGE "Enter CLLI code for YOUR location using full 8 or 11 characters:"
|
|
LOCATE 12,2
|
|
GET S2 11
|
|
|
|
CLEAR
|
|
LOCATE 8,2
|
|
MESSAGE "Enter system ID without 'MI', for example ALBNMN-JCSNMN."
|
|
LOCATE 10,2
|
|
GET S8 13
|
|
LOCATE 13,2
|
|
MESSAGE "Enter system number, for example 1201 / T3X."
|
|
LOCATE 15,2
|
|
GET S9 15
|
|
|
|
TRANSMIT "CGNS"
|
|
TRANSMIT "`""
|
|
TRANSMIT S8
|
|
TRANSMIT "`""
|
|
TRANSMIT "!"
|
|
|
|
CLEAR
|
|
LOCATE 6,2
|
|
MESSAGE "Enter today's date."
|
|
LOCATE 8,2
|
|
MESSAGE "Enter two digit year + <ENTER>"
|
|
LOCATE 8,34
|
|
GET S3 2 ; 2 DIGIT YEAR
|
|
LOCATE 10,2
|
|
MESSAGE "Enter two digit month + <ENTER>. Use 0's if required."
|
|
LOCATE 10,58
|
|
GET S4 2 ; 2 DIGIT MONTH
|
|
LOCATE 12,2
|
|
MESSAGE "Enter two digit day + <ENTER>. Use 0's if required."
|
|
LOCATE 12,56
|
|
GET S5 2 ; 2 DIGIT DAY
|
|
CLEAR
|
|
LOCATE 6,2
|
|
MESSAGE "Enter time."
|
|
LOCATE 8,2
|
|
MESSAGE "Enter two digit hour + <ENTER>. Use 0's if required."
|
|
LOCATE 8,57
|
|
GET S6 2 ; 2 DIGIT HOUR
|
|
LOCATE 10,2
|
|
MESSAGE "Enter two digit minute + <ENTER>. Use 0's if required."
|
|
LOCATE 10,59
|
|
GET S7 2 ; 2 DIGIT MINUTE
|
|
CLEAR
|
|
|
|
;SET TIME DP3025
|
|
TRANSMIT "CT"
|
|
TRANSMIT S6
|
|
TRANSMIT " "
|
|
TRANSMIT S7
|
|
TRANSMIT " !"
|
|
PAUSE 1
|
|
KFLUSH
|
|
RFLUSH
|
|
CLEAR
|
|
|
|
;PROMPT THE USER TO CHECK INPUTS FOR LOCATIONS
|
|
LOCATE 1,2
|
|
MESSAGE "Please verify the following information."
|
|
LOCATE 4,2
|
|
MESSAGE "LOCATION A CLLI CODE = "
|
|
LOCATE 4,26
|
|
MESSAGE S0
|
|
LOCATE 6,2
|
|
MESSAGE "LOCATION B CLLI CODE = "
|
|
LOCATE 6,26
|
|
MESSAGE S1
|
|
LOCATE 8,2
|
|
MESSAGE "LOCAL LOCATION CLLI CODE ="
|
|
LOCATE 8,29
|
|
MESSAGE S2
|
|
LOCATE 10,2
|
|
MESSAGE "SYSTEM ID = "
|
|
LOCATE 10,17
|
|
MESSAGE S8
|
|
LOCATE 12,2
|
|
MESSAGE "SYSTEM NUMBER = "
|
|
LOCATE 12,21
|
|
MESSAGE S9
|
|
LOCATE 17,2
|
|
MESSAGE "IS INFORMATION CORRECT? Y/N + <ENTER>"
|
|
LOCATE 17,44
|
|
GET S8 1
|
|
SWITCH S8
|
|
CASE "Y"
|
|
;DO NOTHING
|
|
ENDCASE
|
|
DEFAULT
|
|
GOTO LABEL1 ; JUMP TO TOP AND ENTER INFORMATION AGAIN
|
|
ENDCASE
|
|
ENDSWITCH
|
|
CLEAR
|
|
LOCATE 8,15
|
|
MESSAGE "DO NOT PRESS ANY KEYS UNTIL CONFIGURATION COMPLETE"
|
|
LOCATE 10,15
|
|
MESSAGE "OK...HERE WE GO..."
|
|
ALARM 1
|
|
PAUSE 2
|
|
|
|
;SET DATE DP3024
|
|
TRANSMIT "CD"
|
|
TRANSMIT S3
|
|
TRANSMIT " "
|
|
TRANSMIT S4
|
|
TRANSMIT " "
|
|
TRANSMIT S5
|
|
TRANSMIT " !"
|
|
PAUSE 1
|
|
|
|
;NAME NODE 1 USING CENTRAL OFFICE CLLI CODE
|
|
TRANSMIT "CGNN1 "
|
|
TRANSMIT "`""
|
|
TRANSMIT S0
|
|
TRANSMIT "`""
|
|
TRANSMIT "!"
|
|
|
|
;NAME NODE 2 USING REMOTE CLLI CODE
|
|
TRANSMIT "CGNN2 "
|
|
TRANSMIT "`""
|
|
TRANSMIT S1
|
|
TRANSMIT "`""
|
|
TRANSMIT "!"
|
|
|
|
;DEFINE SITE
|
|
TRANSMIT "CGS1 1 2 !"
|
|
;TRANSMIT "`""
|
|
;TRANSMIT S0
|
|
;TRANSMIT "`""
|
|
;TRANSMIT S1
|
|
;TRANSMIT " "
|
|
;TRANSMIT "!"
|
|
|
|
;CONFIGURE CUSTOMER OUTPUT POINTS DP3013
|
|
TRANSMIT "CGNO1 "
|
|
TRANSMIT "`"BAY MINOR`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO2 "
|
|
TRANSMIT "`"BAY MAJOR`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO3 "
|
|
TRANSMIT "`"OPT A FAIL`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO4 "
|
|
TRANSMIT "`"OPT B FAIL`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO5 "
|
|
TRANSMIT "`"STX TX`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO6 "
|
|
TRANSMIT "`"STX RX`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO7 "
|
|
TRANSMIT "`"M13 ALARM #1`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO8 "
|
|
TRANSMIT "`"M13 ALARM #2`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO9 "
|
|
TRANSMIT "`"M13 ALARM #3`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO10 "
|
|
TRANSMIT "`"HSA ALARM`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO11 "
|
|
TRANSMIT "`"HSB ALARM`""
|
|
TRANSMIT "!"
|
|
;TRANSMIT "CGNO12 "
|
|
;TRANSMIT "`"DS1 GRP FAIL`""
|
|
;TRANSMIT "!"
|
|
TRANSMIT "CGNO13 "
|
|
TRANSMIT "`""
|
|
TRANSMIT S9
|
|
TRANSMIT "`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO14 "
|
|
TRANSMIT "`"COM EQUIP ALRM`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO15 "
|
|
TRANSMIT "`"NODE #1 CO`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNO16 "
|
|
TRANSMIT "`"NODE #2 REMOTE`""
|
|
TRANSMIT "!"
|
|
|
|
;DELETE ALL EXISTING CUSTOMER OUTPUTS
|
|
TRANSMIT "CGO1 D*!"
|
|
TRANSMIT "CGO2 D*!"
|
|
TRANSMIT "CGO3 D*!"
|
|
TRANSMIT "CGO4 D*!"
|
|
TRANSMIT "CGO5 D*!"
|
|
TRANSMIT "CGO6 D*!"
|
|
TRANSMIT "CGO7 D*!"
|
|
TRANSMIT "CGO8 D*!"
|
|
TRANSMIT "CGO9 D*!"
|
|
TRANSMIT "CGO10 D*!"
|
|
TRANSMIT "CGO11 D*!"
|
|
TRANSMIT "CGO12 D*!"
|
|
TRANSMIT "CGO13 D*!"
|
|
TRANSMIT "CGO14 D*!"
|
|
TRANSMIT "CGO15 D*!"
|
|
TRANSMIT "CGO16 D*!"
|
|
|
|
;CUSTOMER OUTPUTS 1-2
|
|
TRANSMIT "CGO1 AS1 G100 !"
|
|
TRANSMIT "CGO2 AS1 G120 !"
|
|
|
|
;CUSTOMER OUTPUTS 3-9
|
|
TRANSMIT "CGO3 AS1 G107 !"
|
|
TRANSMIT "CGO4 AS1 G108 !"
|
|
TRANSMIT "CGO5 AS1 G101 !"
|
|
TRANSMIT "CGO5 AS1 G102 !"
|
|
TRANSMIT "CGO5 AS1 G103 !"
|
|
TRANSMIT "CGO6 AS1 G104 !"
|
|
TRANSMIT "CGO6 AS1 G105 !"
|
|
TRANSMIT "CGO6 AS1 G106 !"
|
|
TRANSMIT "CGO7 AS1 G109 !"
|
|
TRANSMIT "CGO8 AS1 G110 !"
|
|
TRANSMIT "CGO9 AS1 G111 !"
|
|
|
|
;CUSTOMER OUTPUTS 10-11
|
|
TRANSMIT "CGO10 AS1 M1 MH18 !"
|
|
TRANSMIT "CGO10 AS1 M2 MH18 !"
|
|
TRANSMIT "CGO10 AS1 M3 MH18 !"
|
|
TRANSMIT "CGO11 AS1 M1 MH19 !"
|
|
TRANSMIT "CGO11 AS1 M2 MH19 !"
|
|
TRANSMIT "CGO11 AS1 M3 MH19 !"
|
|
;TRANSMIT "CGO12 AS1 M1 1H2 !"
|
|
;TRANSMIT "CGO12 AS1 M2 1H2 !"
|
|
;TRANSMIT "CGO12 AS1 M3 1H2 !"
|
|
;TRANSMIT "CGO12 AS1 M1 1H3 !"
|
|
;TRANSMIT "CGO12 AS1 M2 1H3 !"
|
|
;TRANSMIT "CGO12 AS1 M3 1H3 !"
|
|
|
|
;CUSTOMER OUTPUT 13, 14
|
|
TRANSMIT "CGO13 AS1 G100 !"
|
|
TRANSMIT "CGO13 AS1 G120 !"
|
|
TRANSMIT "CGO14 AS1 G112 !"
|
|
|
|
;CUSTOMER OUTPUTS 15, 16
|
|
TRANSMIT "CGO15 AN1 G100 !"
|
|
TRANSMIT "CGO15 AN1 G120 !"
|
|
TRANSMIT "CGO16 AN2 G100 !"
|
|
TRANSMIT "CGO16 AN2 G120 !"
|
|
|
|
;SET TO AUTOMATIC CONTROL
|
|
TRANSMIT "CGO1 CA!"
|
|
TRANSMIT "CGO2 CA!"
|
|
TRANSMIT "CGO3 CA!"
|
|
TRANSMIT "CGO4 CA!"
|
|
TRANSMIT "CGO5 CA!"
|
|
TRANSMIT "CGO6 CA!"
|
|
TRANSMIT "CGO7 CA!"
|
|
TRANSMIT "CGO8 CA!"
|
|
TRANSMIT "CGO9 CA!"
|
|
TRANSMIT "CGO10 CA!"
|
|
TRANSMIT "CGO11 CA!"
|
|
TRANSMIT "CGO12 CA!"
|
|
TRANSMIT "CGO13 CA!"
|
|
TRANSMIT "CGO14 CA!"
|
|
TRANSMIT "CGO15 CA!"
|
|
TRANSMIT "CGO16 CA!"
|
|
;
|
|
;DEFINE CUSTOMER OUTPUT 12
|
|
TRANSMIT "CGO12 D*!"
|
|
TRANSMIT "CGNO12 "
|
|
TRANSMIT "`"EXT ALM`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGO12 AN2 G118 !"
|
|
;also attach to pt 13 for alarm center ID
|
|
TRANSMIT "CGO13 AN2 G118 !"
|
|
;
|
|
;DEFINE CUSTOMER INPUTS
|
|
TRANSMIT "CGNI1 "
|
|
TRANSMIT "`"SMOKE DET.`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNI2 "
|
|
TRANSMIT "`"SUMP PUMP`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNI3 "
|
|
TRANSMIT "`"OPEN DOOR`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNI4 "
|
|
TRANSMIT "`"AC PWR FAIL`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNI5 "
|
|
TRANSMIT "`"HI-LO TEMP`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNI6 "
|
|
TRANSMIT "`"RECT. FAIL`""
|
|
TRANSMIT "!"
|
|
TRANSMIT "CGNI7 "
|
|
TRANSMIT "`"BATT FLOAT`""
|
|
TRANSMIT "!"
|
|
;
|
|
;ADD CONDITIONS TO CUSTOMER OUTPUT 1
|
|
TRANSMIT "CGO1 AN2 SS5 !"
|
|
TRANSMIT "CGO1 AN2 SS6 !"
|
|
TRANSMIT "CGO1 AN2 SS7 !"
|
|
;
|
|
;ADD CONDITIONS TO CUSTOMER OUTPUT 2
|
|
TRANSMIT "CGO2 AN2 SS1 !"
|
|
TRANSMIT "CGO2 AN2 SS2 !"
|
|
TRANSMIT "CGO2 AN2 SS3 !"
|
|
TRANSMIT "CGO2 AN2 SS4 !"
|
|
;
|
|
;PER JOE OLSZTYN SWITCHING SYSTEMS STAFF
|
|
;LEAVE PERFORMANCE MONITORING AT FACTORY DEFAULT
|
|
;DISABLE BLUE INSERTION FOR POINT TO POINT SYSTEMS
|
|
;IN A MULTIPOINT SYSTEM BLUE INSERTION SHOULD BE ENABLED.
|
|
|
|
;ENABLE ALARM LOGGER
|
|
TRANSMIT "CAD!"
|
|
|
|
;DISABLE BLUE INSERTION NODE 1 DP3019
|
|
TRANSMIT "CN1 T1 BE!"
|
|
TRANSMIT "CN1 T2 BE!"
|
|
TRANSMIT "CN1 T3 BE!"
|
|
|
|
;ENABLE PARITY CORRECTION NODE 1 DP3020
|
|
TRANSMIT "CN1 T1 PE!"
|
|
TRANSMIT "CN1 T2 PE!"
|
|
TRANSMIT "CN1 T3 PE!"
|
|
|
|
;ENABLE RX OVERHEAD NODE 1 DP3021
|
|
TRANSMIT "CN1 T1 RE!"
|
|
TRANSMIT "CN1 T2 RE!"
|
|
TRANSMIT "CN1 T3 RE!"
|
|
|
|
;ENABLE TX OVERHEAD NODE 1 DP3022
|
|
TRANSMIT "CN1 T1 TE!"
|
|
TRANSMIT "CN1 T2 TE!"
|
|
TRANSMIT "CN1 T3 TE!"
|
|
|
|
;SIGNAL DEGRADE 10E-8 NODE 1 DP3158
|
|
TRANSMIT "CN1 T1 S8!"
|
|
TRANSMIT "CN1 T2 S8!"
|
|
TRANSMIT "CN1 T3 S8!"
|
|
|
|
;DISABLE BLUE INSERTION NODE 2 DP3019
|
|
TRANSMIT "CN2 T1 BE!"
|
|
TRANSMIT "CN2 T2 BE!"
|
|
TRANSMIT "CN2 T3 BE!"
|
|
|
|
;ENABLE PARITY CORRECTION NODE 2 DP3020
|
|
TRANSMIT "CN2 T1 PE!"
|
|
TRANSMIT "CN2 T2 PE!"
|
|
TRANSMIT "CN2 T3 PE!"
|
|
|
|
;ENABLE RX OVERHEAD NODE 2 DP3021
|
|
TRANSMIT "CN2 T1 RE!"
|
|
TRANSMIT "CN2 T2 RE!"
|
|
TRANSMIT "CN2 T3 RE!"
|
|
|
|
;ENABLE TX OVERHEAD NODE 2 DP3022
|
|
TRANSMIT "CN2 T1 TE!"
|
|
TRANSMIT "CN2 T2 TE!"
|
|
TRANSMIT "CN2 T3 TE!"
|
|
|
|
;SIGNAL DEGRADE 10E-8 NODE 2 DP3158
|
|
TRANSMIT "CN2 T1 S8!"
|
|
TRANSMIT "CN2 T2 S8!"
|
|
TRANSMIT "CN2 T3 S8!"
|
|
|
|
;LINE LEARN ALL MULTIPLEXERS BOTH NODES
|
|
TRANSMIT "CN1 M1 L!"
|
|
TRANSMIT "CN1 M2 L!"
|
|
TRANSMIT "CN1 M3 L!"
|
|
TRANSMIT "CN2 M1 L!"
|
|
TRANSMIT "CN2 M2 L!"
|
|
TRANSMIT "CN2 M3 L!"
|
|
|
|
;CONFIGURATION IS COMPLETE EXIT THE PROGRAM
|
|
CLEAR
|
|
ALARM 1
|
|
LOCATE 10,20
|
|
MESSAGE "......CONFIGURATION COMPLETE......"
|
|
LOCATE 14,17
|
|
MESSAGE "CONTINUE WITH SECTION 5 OF CERTIFICATION"
|
|
ALARM 2
|
|
PAUSE 5
|
|
EXIT
|
|
|
|
|
|
----------------------------------------------------------------------------
|
|
Glossary of Terms
|
|
|
|
4W Four Wire
|
|
ACO Alarm Cut-Off
|
|
ACTV Active (module -- carrying traffic)
|
|
AGC Automatic Gain Control
|
|
AIS Alarm Indication Signal -- indicates an alarm upstream
|
|
AMI Alternate Mark Inversion -- a technique by which the polarity of
|
|
alternate pulses is inverted
|
|
APD Avalanche Photo Diode -- used for detecting pulses of light
|
|
at the receive end of an optical fiber
|
|
AUD Audible alarm
|
|
BDF Battery Distribution Frame
|
|
BER Bit Error Rate
|
|
BIP Bit Interleave Parity
|
|
BPV Bipolar Violation -- signal is not alternating as expected
|
|
CAMMS Centralized Access Maintenance and Monitoring System --
|
|
a bay-mounted shelf with push buttons and an luminescent display,
|
|
which is used to control FMT-150 networks, as well as other
|
|
Northern Telecom transmission equipment
|
|
CDP Centralized Display Panel
|
|
CEV Controlled Environment Vault
|
|
CO Central Office
|
|
CPC Common Product Code -- a Northern Telecom code used to identify
|
|
equipment
|
|
DDD Direct Distance Dialing
|
|
DM-13 Digital Multiplexer which multiplexes between DS-1/1C/2 signals
|
|
and DS-3 signals
|
|
DNA Dynamic Network Architecture
|
|
E2A A serial interface for alarm polling of equipment
|
|
FE Frame Error
|
|
FER Frame Error Rate
|
|
FL Frame Loss
|
|
FLC Frame Loss Counter
|
|
FLS Frame Loss Seconds
|
|
FPD Future Product to be Developed
|
|
Group A multiplexed signal made up of four DS-1s, two DS-1Cs, or
|
|
one Ds-2
|
|
Hub An FMT-150 site which branches one 150 Mb/s signal into two or
|
|
three signals, in different directions, without sacrificing
|
|
OA & M continuity
|
|
LBR Loopback Request
|
|
MCU Maintenance Control Unit
|
|
MM Multimode Optical Fiber
|
|
MSB Most Significant Bit
|
|
Muldem Multiplexer/demultiplexer
|
|
NRZ Non-Return to Zero
|
|
OTT Optical Termination Tray
|
|
PEC Product Engineering Code -- a Norther Telecom code used to identify
|
|
equipment. The preferred code to be used when ordering Northern
|
|
Telecom equipment.
|
|
PER Parity Error Rate
|
|
PES Parity Error Seconds
|
|
RTO Ready To Order
|
|
SCU Service Channel Unit
|
|
SMB Sub-Miniature BNC type connector
|
|
SR Stuff Request
|
|
STX (Pseudo) Synchronous Transport Signal: First Level at
|
|
49.92 Mb/s (Northern Telecom)
|
|
TBOS Telemetry Byte Oriented System
|
|
VIS Visual Alarm
|
|
WDM Wavelength Division Multiplexing
|
|
XOW Express Orderwire
|
|
|